  • This sensor can be used to make measurements of the level of free-oxygen in air or dissolved oxygen in water. The free-oxygen in air mode is used to measure changes in oxygen levels during combustion or in reactions that produce oxygen (hydrogen peroxide decomposition). The Dissolvedoxygen mode is useful in the study of photosynthesis. The oxygen sensor is designed for use both in the school laboratory and in the field. It employs easy-to-use polarographic (Clark) technology and replaceable membranes are available for it. The electrode itself is constructed of Delrin® for durability. With its integral thermistor, it provides dependable  temperature-compensated measurements. The thermistor is housed in stainless steel and sealed on the electrode's outer

    wall providing fast, accurate readings.

     

    Sensor Calibration:

    The sensor should be connected to a voltage source (the USB module plugged into a computer, Edu-Logger's™ Display unit or Battery module). For free Oxygen, calibration of the probe is simply achieved in open air, taking this as a standard level of 20.9% (assuming stable level in the Earth's atmosphere at sea-level) and pressing the push-button on the sensor's box for about 3 seconds when the readings are stable. The sensor will then be calibrated at 20.9%. In liquid, the sensor is calibrated to 100% in an Oxygen saturated solution.

     

    Some datalogging O2 sensors require both zero-oxygen solution and 100% calibration bottle since their sensors are not factory calibrated. The Edu-Logger sensor is, so they do not need both points (0 and 100%) and therefore there is no need for the zero-oxygen solution. For a 100% point setting we recommend the use of a 50 ml plastic syringe to pump air into the water and set the 100% saturation point.

    As with all Edu-Logger Sensors this must be used with the Edulogger USB module or the Wi-Fi module

    View full details

    • Bullet Point Converts the measured parameter into a processed value (°C, °F, Lux, dB, mA, V, etc.)
    • Bullet Point Sends the data in digital form to a viewer unit, any kind of computer or tablet
    • Bullet Point Saves up to 5 experiments in its flash memory
    • Bullet Point Calibration is done by pressing a push-button
    • Bullet Point Changing ranges and gains is done through software
    • Bullet Point Experiments run with or without a computer
    • Bullet Point Saved experiments in the Logger Sensor can be uploaded to a computer at any time
    • Bullet Point The modular plug and play system allows the connection of sensors in a chain, in any order
    • Bullet Point Each sensor is in itself a full data acquisition system
    • Bullet Point Unbeatable value for money
    • Bullet Point Robust hardware and attractive design
    • Bullet Point Very simple operation
    • Bullet Point No cable clutter and therefore a very simple construction of experiments
    • Bullet Point System allows wireless connection
  • Nobody has left a review for this product yet, be the first to do so. Leave Review

Technical Specification

Specifications:

Experiment Duration: 1 second to 31 days.

 

Range and operation modes:-

0 to 25% (in air)

0 to 125% (dissolved)

 

ADC resolution:-

12 bit

 

Resolution:-

0%

0.01%

 

Max Sample Rate (S/sec):-

100 (subject to experiment duration)

 